Message: 
 | 
 
Unable to Set Comm Port 
 | 
| 
 
Possible Solution: 
  
 | 
 
Computers with Vadem controllers (see your computer's manual) may give a false "Unable to Set Comm Port" error message during installation.  If  you receive this message and are installing your Megahertz modem in a computer with a Vadem controller, ignore the message.  
 | 
| 
 
  
 | 
 
  
 | 
| 
 
Message: 
 | 
 
COM ports 1-4 supported, defaulting to COM2 (if available). 
 | 
| 
 
Possible Solutions: 
 | 
 
An invalid /c switch was entered on the command line for the DOS Enabler.   Re-enter the line with the correct /c value switch. 
Using a text editor such as EDIT, change the /c switch to the COM port specified in the ENABLE.INI file. 
 | 
| 
 
		 
 | 
 
  
 | 
| 
 
Message: 
 | 
 
Slots A to H supported, defaulting to Slot A. 
 | 
| 
 
Possible Solutions: 
 | 
 
An invalid /s switch was entered on the command line for the DOS Enabler. Re-enter the line with the correct /s switch.  
Using a text editor such as EDIT, change the number of PC Card slots specified in the ENABLE.INI file. 
 | 
| 
 
	 
 | 
 
  
 | 
| 
 
Message: 
 | 
 
Slot X Is Not Supported 
 | 
| 
 
Possible Solutions: 
 | 
 
An invalid /s switch was entered on the command line for the DOS Enabler.  Re-enter the line with the correct /s value switch. 
Using a text editor such as EDIT, change the value of number of slots in the ENABLE.INI file. 
 | 
| 
 
  
 | 
 
		 
 | 
| 
 
		Message: 
 | 
 
The Attribute Memory Address must be in the range of A000-EF00. 
 | 
| 
 
Possible Solutions: 
 | 
 
		An invalid /p switch was entered on the command line for the DOS Enabler.  Re-enter the line with the correct /p switch. 
Using a text editor such as EDIT, change the memory address value specified in the ENABLE.INI file. 
 | 
| 
 
		 
 | 
 
  
 | 
| 
 
Message: 
 | 
 
The Attribute Memory Address must be divisible by 100h. 
 | 
| 
 
Possible Solutions: 
 | 
 
	An invalid /p switch was entered on the command line for the DOS Enabler. Re-enter the line with the correct /p switch. 
Using a text editor such as EDIT, change the /p switch to the memory address value specified in the ENABLE.INI file. 
 | 
| 
 
	 
 | 
 
  
 | 
| 
 
Message: 
 | 
 
Could not find a PC Card to install. 
 | 
| 
 
Possible Solution: 
 | 
 
No PC Card is inserted in the slot. Insert a functioning modem PC Card.  
 | 
| 
 
  
 | 
 
  
 | 
| 
 
Message: 
 | 
 
Please select a valid delay in the range of 0-10000. 
 | 
| 
 
Possible Solution: 
 | 
 
An invalid /d switch was entered on the command line for the DOS Enabler.  Re-enter the line with the correct /d switch. 
 | 
| 
 
  
 | 
 
  
 | 
| 
 
Message: 
 | 
 
The flag XXX is not recognized. 
 | 
| 
 
Possible Solution: 
 | 
 
An invalid switch was entered on the command line.  Re-enter the line with the correct switch. 
 | 
| 
 
  
 | 
 
  
 | 
| 
 
Message: 
 | 
 
Unable to configure the modem! 
 | 
| 
 
Possible Solution: 
 | 
 
The card cannot be configured. Run Enable again, selecting a different COM port, IRQ, or memory address (refer to your computer's manual for information on these settings). 
 | 
| 
 
  
 | 
 
  
 | 
| 
 
Message: 
 | 
 
Unrecognized card. 
 | 
| 
 
Possible Solution: 
 | 
 
Enable does not recognize your PC Card as a modem. Run Enable again, selecting a different COM port, IRQ, or memory address (refer to your computer's manual for information on these settings). 
 | 
| 
 
  
 | 
 
  
 | 
| 
 
Message: 
 | 
 
Error:  No modem IRQs are available for this card. 
 | 
| 
 
Possible Solution: 
  
 | 
 
Check your computer's configuration. The modem IRQ defined cannot be used, or is being used by another PC Card. 
 |